Hitachi Inverter SJ series P1 3-phase 200V Inverter for 0.4kw-55kw Motors

Hitachi Inverter SJ series P1 3-phase 200V Inverter  for 0.4kw-55kw Motors

           Extro Machinery Trading Sdn Bhd

 

 

 

Hitachi Inverter SJ series P1 3-phase 200V Inverter  for 0.4kw-55kw Motors

 

3-phase 200V 0.4 - 55kW
3-phase 400V 0.75 - 132kW

 

Features

 

1.        Easy access to all the functionality.

 Intuitive, easy-to-use LCD operator is standard.

  • Easily monitor, set, or review operational data and parameters.
  • Real-time at the alarm occurrence is recorded.
  • Multiple languages.

Direct field replacement, when needed

  • Panel mounting portion is supplied as separate part. (5.5kW or more) Even if its body size is different, it is possible to correspond in flexible ways.
  • Screw type terminal block is also abailable.
  • Cooling fan and the main circuit capacitor is designed for 10 years life.
  • Monitor lifetime prediction functions.
  • Easy data copy to multiple inverters.

Control circuit terminal designed for easy wiring

  • Easy to use screw less terminal block for control terminal block.
  • Modbus communication is standard. 2 communication terminals provided for Modbus communication as standard.
  • 0/10V and 4 to 20mA inputs and as well as output are easily selected via DIP switch.

Programming ease through the use of 24 VDC to power up inverter CPU memory

  • Normal power supply (R0, T0) to CPU. Also possible to utilize an external 24VDC control power supply.

Control Simulation Logic operation without direct motor output

  • The simulation mode makes it easier to verify connection with the system control equipment.

Quick diagnose during failure

  • The SJ-P1 automatically stores internal data in retentive memory*. Users can upload the data to a PC for review and diagnosis of issue.

Easy customize by PC configuration software

  • PC setting software.
  • Easy customizationto your own inverter.

 

 

2.        A High Performance drive for the most demanding of applications.

"Smooth operation" in critical and demanding applications, such as vertical lift

  • High starting torque at low speed range while in control of heavy loads. (ND rating). [Sensor less vector control(SLV)] [OHz sensor less vector control]
  • Decreasing overshoot and undershoot contributes to smooth and stabilized operation with reduced load shock. [Gain mapping Function]

Save on spare control costs

  • Our multi-mode inverter can control both your induction motor, or permanent magnet AC motor. All while offering programmable current limit to protect from demagnetization of the PM motor.
  • Optimize performance. [Auto-tuning function]

"High speed rotation" for non-traditional applications

  • 590Hz at the maximum operation is available for precise metal processing. For PM motor, also up to 400Hz. (actual output frequency depends on motor)

Reduce trips on acceleration and deceleration

  • Automatic speed adjustment manages ideal acceleration / deceleration speed to reduce the trip possibility from over current, over voltage, and impact load.

 

 

3.        Versatility through multi mode operation, to meet your specific application needs.

Certified "functional safety" international standard

  • Certified functional safety. (Certification in process)
  • SS1, SLS and others are available with slot-in option cassette. (In design phase)

"Save space and save cost" by multi rating function!

  • Triple-rated for Induction motor for various applications is selectable. Dual-rated for PM motor control. Multiple rating helps to save space and cost.

Easy customize with "Slot-in" option cassette

  • Cassette type option boards for intuitive installation.
  • Network options available for system expansion.

"High quality" to comply international standards

  • Corresponds to the EC directive, UL and cUL in order to guarantee the quality and safety. Equipped with a quality that is recognized in Europe. 
  • Built-in noise filters corresponding to the European EMC Directive. (IEC61800-3 2nd Environment Category C3)
  • Since complies with the RoHS, Environmental considerations also sufficient.

Braking circuit is built-in. Further "Space and Cost saving"

  • The regenerative braking circuit is built-in, therefore a separate regenerative braking unit (BRD) is not necessary. Saving space and cost.

 

 

4.      Hitachi's ProDriveNext Software.

5.      Easily Customizable.(EzSQ and EzCOM)

 

 

200V class specifications

 

Model name(P1-☐☐☐-L) 00044 00080 00104 00156 00228 00330 00460 00600 00800 00930 01240 01530 01850 02290 02950
Applicable motor capacity
(4 poles) (kW)*1
VLD 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75
LD 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75
ND 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55
Output Rated output current
(A)
VLD 4.4 8.0 10.4 15.6 22.8 33.0 46.0 60.0 80.0 93.0 124.0 153.0 185.0 229.0 295.0
LD 3.7 6.3 9.4 12.0 19.6 30.0 40.0 56.0 73.0 85.0 113.0 140.0 169.0 210.0 270.0
ND 3.2 5.0 8.0 11.0 17.5 25.0 32.0 46.0 64.0 76.0 95.0 122.0 146.0 182.0 220.0
Overload current rating*2 VLD 110% 60sec / 120% 3sec
LD 120% 60sec / 150% 3sec
ND 150% 60sec / 200% 3sec
Rated output voltage 3-phase (3-wire) 200 to 240V (corresponding to input voltage)
Rated capacity (kVA) 200V VLD 1.5 2.8 3.6 5.4 7.9 11.4 15.9 20.8 27.7 32.2 43.0 53.0 64.1 79.3 102.2
LD 1.3 2.2 3.3 4.2 6.8 10.4 13.9 19.4 25.3 29.4 39.1 48.5 58.5 72.7 93.5
ND 1.1 1.7 2.8 3.8 6.1 8.7 11.1 15.9 22.2 26.3 32.9 42.3 50.6 63.0 76.2
240V VLD 1.8 3.3 4.3 6.5 9.5 13.7 19.1 24.9 33.3 38.7 51.5 63.6 76.9 95.2 122.6
LD 1.5 2.6 3.9 5.0 8.1 12.5 16.6 23.3 30.3 35.3 47.0 58.2 70.3 87.3 112.2
ND 1.3 2.1 3.3 4.6 7.3 10.4 13.3 19.1 26.6 31.6 39.5 50.7 60.7 75.7 91.5
Input Rated input AC voltage*3 Main circuit power supply: 3-phase 200 to 240V 50/60Hz, 
Control power supply: 1-phase 200 to 240V 50/60Hz
Permissible AC voltage / Frequency fluctuation AC voltage: 170 to 264V 50/60Hz, Frequency: ±5%
Power supply capacity (kVA)*4 VLD 2.0 3.6 4.7 7.1 10.3 15.0 20.9 27.2 36.3 42.2 56.3 69.4 83.9 103.9 133.8
LD 1.7 2.9 4.3 5.4 8.9 13.6 18.1 25.4 33.1 38.6 51.3 63.5 76.7 95.3 122.5
ND 1.5 2.3 3.6 5.0 7.9 11.3 14.5 20.9 29.0 34.5 43.1 55.3 66.2 82.6 99.8
Carrier frequency range*5 VLD 0.5 to 10.0kHz
LD 0.5 to 12.0kHz
ND 0.5 to 16.0kHz
Starting torque*6 200%/0.3Hz
Braking Regenerative Braking Internal BRD circuit (external discarge resistor) Ext. regen. braking unit
Minimum resistance value (Ω) 50 50 35 35 35 16 10 10 7.5 7.5 5 - - - -
Protective structure IP20 - UL Open Type
Aprox. weight (kg) 3 3 3 3 3 6 6 6 10 10 10 22 33 33 47

*1 The applicable motor refers to Hitachi standard 3-phase motor (4-pole). To use other motors, be sure to prevent the rated motor current (50Hz) from exceeding the rated output current of the inverter.

*2 Electronic thermal protection is valid in accordance to derating.

*3 In order to comply with the Low Voltage Directive (LVD), it must be connected to a neutral grounding supply. 200V class: -Pollution degree 2 -Overvoltage category 3. 400V class: -Pollution degree 2 -Overvoltage category 3 (In the case the input supply is 380 to 460Vac) -Overvoltage category 2 (If the input supply is 460Vac or more).

*4 The power supply capacity is the value of the output rated current at 220V / 440V. The impedance at the supply side may be affected by the wiring, breaker, input reactor, etc.

*5 Carrier frequency may be limited in the range according to the use of drive.

*6 The values for the sensorless vector control are assigned according to the values in the ND rating in the Hitachi standard motor table. Torque characteristics may vary by the control system and the motor in use.

 

 